
Page | 35
Accessories
Oakton buffers for meters with 0.01 resolution are standardized against
NIST-certified pH references within 0.01 pH at 77°F (25°C). Store
buffers away from direct sunlight.
NIST Certified pH Buffer Solutions
Electrode stand with swivel arm allows
convenient hands-free operation. Holds
up to four standard size electrodes (14
mm diameter) and one ATC probe.
• Weighted 6-inch diameter base
allows you to pivot holder 360 ° for
more flexibility
• Arm allows you to move electrode
side to side or up and down while
keeping electrode at a constant
verticle angle
Electrode Stand with Swivel Arm
Order Code Description
ECPHELSTDC Electrode stand with swivel arm
Tips for calibration solutions
Solutions of known value allow you to adjust your testing system to
measure your samples unknown pH, TDS, Conductivity, ORP or
Salinity more precisely. For best accuracy:
l Perform standardizations with fresh standard solutions. Never
pour used solutions back into the bottle; always discard after
using
l Use standards that frame the range of the samples you are
testing i.e., directly above and below the expected value of
your sample
l Calibrate your system before each use or set of uses
Order Code Description
Oakton NIST certified pH Buffer Solutions (500 ml)
00654-01 pH 1.68 buffer solution
00654-00 pH 4.01 buffer solution
00654-04 pH 7.00 buffer solution
00654-08 pH 10.00 buffer solution
00654-12 pH 12.45 buffer solution
Oakton NIST certified pH Buffer Solutions (500 ml, pack of 12 bottles)
05942-21 pH 4.01 buffer solution
05942-41 pH 7.00 buffer solution
05942-61 pH 10.00 buffer solution
Buffer solutions for meters with 0.001 resolution are accurate to either
±0.002 pH unit (pH 4 and 7 buffers) or ±0.005 pH unit (pH 10 buffer)
when referenced to NIST-certified reference materials at 77°F (25°C).
Oakton NIST certified High Accuracy pH Buffer Solutions (500 ml)
05942-26 pH 4.01 buffer solution
05942-46 pH 7.00 buffer solution
05942-66 pH 10.00 buffer solution
High-Accuracy NIST pH Buffer Solution
NIST pH Buffer Solution
pH Electrode Care and Maintenance
Storing
The sensor should never be stored dry. It is best to store electrodes
in clean containers filled with pH storage solution, EC-RE005 or pH
7.00 buffer. Do not store an electrode in distilled or deionised water
- this will cause ions to leach out of the glass bulb and render your
electrode useless
Cleaning
l For general cleaning: Soak the pH electrode in 0.1 M HCl or 0.1
M HNO3 for 20 minutes. Rinse well in tap water before use.
l For removing stubborn deposits and bacteria: Soak the pH
electrode in a 1:10 dilution of household laundry bleach for 10
minutes. Rinse thoroughly before use.
l For removal of oil and grease: Rinse the pH electrode in mild
detergent or methyl alcohol. Wash in water before use.
l For removal of protein deposits: Soak the pH electrode in 1%
pepsin in 0.1m HCl (EC-DPC-BT) for 5 minutes. Rinse well in
water before use.
Precision pH Simulator
The Eutech pH-millivolt simulator is a
handy, easy-to-use service tool for
testing the accuracy of your pH meter.
Used for trouble-shooting and fault
diagnosis of meters, the simulator
works with most pH/redox instruments
with BNC connectors. Simulator comes
with a BNC cable and a sturdy rubber
boot which doubles up as a stand.
• Push button pH/mV selection
• pH accuracy of ±0.05; mV range of ±2
• USA/NIST pH buffer standards simulation
• 16 combination values
• 1 G? high input impedance test
• Large display with bright LED
• Splashproof keypad
• Protective rubber boot doubles up as stand
• Power-saving meter runs on 4 ‘AAA’ x 1.4 V batteries
Order Code Description
ECPHSIMULATOR Precision hi-low impedence and multiple buffer pH simulator
(with BNC-BNC cable provided)
Page | 34
Accessories
Buffers and calibration solutions packed in durable plastic bottles –
convenient for laboratory use.
Buffer & Calibration Solutions
Calibration Sachets (20 x 20 ml Per Box)
NIST-traceable sachets for quick, accurate and convenient calibrations.
Simply insert electrode into sachet pack, calibrate, rinse and discard
sachet – no separate container needed!
Order Code Description
pH Buffer Sachets (20 x 20 ml Per Box)
ECBU4BS pH 4.01 buffer sachets (NIST traceable)
ECBU7BS pH 7.00 buffer sachets (NIST traceable)
ECBU10BS pH 10.01 buffer sachets (NIST traceable)
ECRINWT pH deionized water rinse sachets (NIST traceable)
Conductivity/Salinity Sachets (20 x 20 ml Per Box)
ECCON10BS 10 µS/cm KCl Conductivity sachets
ECCON447BS 447 µS/cm KCl Conductivity sachets
ECCON1413BS 1413 µS/cm KCl Conductivity sachets
ECCON2764BS 2764 µS/cm KCl Conductivity sachets
ECCON15000BS 15000 µS/cm KCl Conductivity sachets
ECCON3000BS 3000 ppm KCL Salinity calibration sachets
Order Code Description
pH Buffer Solutions (1 liter Per Bottle)
ECBU4BTC1LIT pH 4.01 buffer solution (Red)
ECBU7BTC1LIT pH 7.00 buffer solution (Yellow)
ECBU10BTC1LIT pH 10.01 buffer solution (Blue)
pH Buffer Solutions (480 ml Per Bottle)
ECBU1BT pH 1.68 buffer solution
ECBU4BT pH 4.01 buffer solution
ECBU686BT pH 6.86 buffer solution
ECBU7BT pH 7.00 buffer solution
ECBU9BT pH 9.00 buffer solution
ECBU918BT pH 9.18 buffer solution
ECBU10BT pH 10.01 buffer solution
ECBU12BT pH 12.45 buffer solution
ECDPCBT Protein cleaning solution for pH electrode
ECRE005 Storage solution for pH electrode
ECRE006 Storage solution for 620 series electrode
ORP Solutions (480 ml Per Bottle)
ECORPPRE Pre-treatment solution (475 mV)
ECORPQUIN Quinhydrone 255 (255 mV, ±15 mV @ 25 ºC)
ECORPQUIN086 Quinhydrone 86 (86 mV)
Conductivity Standard Solution (480 ml Per Bottle)
ECCON84BT 84 µS/cm KCl calibration solution
ECCON100BT 100 µS/cm KCl calibration solution
ECCON500BT 500 µS/cm KCl calibration solution
ECCON1413BT 1413 µS/cm KCl calibration solution
ECCON2764BT 2764 µS/cm KCl calibration solution
ECCON1288BT 12.88 mS/cm KCl calibration solution
ECCON1118BT 111.8 mS/cm KCl calibration solution
ECCON5000BT 5.0 mS/cm KCl calibration solution
TDS 442 Standard Solutions (480 ml Per Bottle)
EC44250BT 50 ppm 442 calibration solution
EC442300BT 300 ppm 442 calibration solution
EC4421000BT 1000 ppm 442 calibration solution
EC4423000BT 3000 ppm 442 calibration solution
Salinity (NaCl) Standard Solutions (480 ml Per Bottle)
ECNACL5PPT 5 ppt Nacl calibration solution
ECNACL25PPT 25 ppt Nacl calibration solution
ECNACL45PPT 45 ppt Nacl calibration solution
Refilling Reference Electrolytes (480 ml Per Bottle)
ECRE001 Saturated potassium chloride with silver chloride for single junction
pH electrodes
ECRE002 Saturated potassium chloride for double junction pH electrodes
ECRE003 Sodium chloride
ECRE004 Ammonium chloride
ECRE015 Lithium chloride in ethylene glycerol for organic samples
Kommentare zu diesen Handbüchern